Description
Feature description
It's crucial to note that in many scenarios, the transmission network parameters are presented in the per-unit system. This allows us to make the transformer equivalent and remove it. However, the current dcopf_transmission.jl code does not yet support this per-unit system.
Furthermore, it seems that the current code does not support the scenario where DClines and AClines are both presented in the system, is it true?
Motivation
No response
Implementation strategy
Although we can put voltage as 1 and reactance as per unit * 100MVA to circumvent the situation, we should be clear about that.